Typical Yvc-8311 High Speed Sewing Machine Control Box User Manual Online

| Pin | Signal | Function | | :--- | :--- | :--- | | 1 | GND | Signal ground | | 2 | +5V | Encoder power | | 3 | A+ | Encoder channel A | | 4 | B+ | Encoder channel B | | 5 | P1 | Foot pedal (wiper) | | 6 | P2 | Foot pedal (trim signal) | | 7 | SOL+ | Trimmer solenoid (24V) | | 8 | SOL- | Solenoid return | | 9 | SW1 | Safety switch (presser foot) | | 10 | SW2 | Pedal neutral detection |

Note: Pinouts for the 5-pin motor power connector are labeled U, V, W, GND, and Brake. To access parameters, press and hold P for 3 seconds while the machine is stopped. Use the + / - buttons to navigate. | Pin | Signal | Function | |

| Indicator | Color | Status Meaning | | :--- | :--- | :--- | | | Green | Control box powered. | | ERR | Red | Fault detected (overcurrent/overvoltage). | | RUN | Blue | Motor receiving pulse signal. | | UP | Yellow | Needle at top dead center. | | Indicator | Color | Status Meaning |

Follow us for more updates

  • Linkedin
  • Instagram
  • Wix Twitter page
  • Youtube
ERN logo en tekst.png
EU logo.png
Erasmus MC logo.png

ERN CRANIO is funded by the European Union. The content of this website represents the views of the author only and it his/her sole responsibility; it cannot be considered to reflect the views of the European Commission and/or the Health and Digital Executive Agency (HaDEA) or any other body of the European Union. The European Commission and the agency do not accept any responsibility for use that may be made of the information it contains. 